15 articles
Biofuel and HVO in Oil Boilers: Which Boilers Accept HVO, OFTEC Guidance and Future-Proofing for Net Zero
HVO (paraffinic diesel BS EN 15940): 70–88% lifecycle CO₂ reduction, manufacturer approval check required, OFTEC re-commissioning, difference from FAME biodiesel (unsuitable for boilers)
Building Regs Part J and Oil Heating: Appliance Efficiency Ratings, Flueing and Combustion Air Requirements
Condensate Pipe Requirements for Oil Condensing Boilers: Trap Depths, External Pipe Insulation and Soakaway Rules
Condensate pipe sizing (22mm internal, 32mm external), 75mm trap seal, discharge routes (foul drain preferred, soakaway rules), freeze prevention and thawing procedure
Kerosene vs Gas Oil: C2 vs D Grade Fuel, Which Boilers Burn Which and Why Fuel Type Matters for Servicing
BS 2869 Class C2 kerosene vs Class D gas oil (red diesel): viscosity impact on atomisation, why wrong fuel causes lockout and sooting, diesel bug risk and fuel identification
OFTEC Competent Person Scheme: Notifiable Oil Work, Building Control Notifications and What Self-Certification Covers
OFTEC registration by individual engineer (not company), notifiable oil works, self-certification via OFT105, registration categories (101 domestic, 105 tanks), Building Regulations Part J
OFTEC OFT105 Commissioning: What the Record Covers, Combustion Analysis and Handover to Customer
OFTEC Registration OFT101: How to Register, Scope of Competence, Self-Certification Rights and Annual Renewal
Oil Boiler Fault Finding: No Ignition, Lockout Causes, Smoke, Sooting and Pressure Gauge Readings
No ignition, lockout causes, photocell diagnosis, pump pressure testing, combustion analysis targets (CO₂ 12–13%, Bacharach 0–1), sooting remediation decision tree
Oil Boiler Service Procedure: Nozzle Replacement, Combustion Analysis Targets, Flue Draught and Fire Valve Check
Oil Fire Valve Requirements: Remote Sensor Siting, Manual Resetting and Part J Compliance
Fusible link fire valve: 95°C operating temperature, sensor siting 100–500mm above appliance, manual reset only, OFTEC OFS T200, annual inspection requirement
Oil Heating System Flushing and Chemical Treatment: Sludge Removal, Inhibitor Dosing and OFTEC Guidance
Power flushing vs chemical flush vs MagnaCleanse for magnetite removal, BS 7593:2019 inhibitor dosing, inhibitor compatibility with aluminium heat exchangers, OFT105 recording
Oil Storage Tank Regulations: OFTEC OFS T100, Bunded vs Single-Skin, Secondary Containment and EA Rules
Oil Tank Inspection and Maintenance: Annual Checks, Ultrasonic Testing, Vent Alarms and Filter Replacement
Annual inspection: structural integrity, diesel bug identification, fuel filter replacement, vent alarm testing, ultrasonic thickness testing for steel tanks, bund water management
Oil Tank Siting Rules: Fire Safety Distances, Flood Risk, Ground Conditions and Planning Considerations
Fire safety distances: 760mm from non-fire-rated buildings, 600mm from boundaries, secondary containment (110% bund) for tanks near watercourses, permitted development rules, concrete base spec
Oil to Heat Pump Changeover: OFTEC Decommission Procedure, Tank Cleaning and Pipe Repurposing Options
OFTEC decommission procedure, tank cleaning and waste oil removal, BUS grant (£7,500 ASHP), radiator upsizing for 45°C flow temperature, pipe reuse assessment